Investor Presentaiton slide image

Investor Presentaiton

Criteria JORC Code explanation Sub-sampling techniques and sample preparation Quality of assay data and laboratory tests • Whether logging is qualitative or quantitative in nature. Core (or costean, channel, etc) photography. The total length and percentage of the relevant intersections logged. If core, whether cut or sawn and whether quarter, half or all core taken. If non-core, whether riffled, tube sampled, rotary split, etc and whether sampled wet or dry. For all sample types, the nature, quality and appropriateness of the sample preparation technique. Quality control procedures adopted for all sub-sampling stages to maximise representivity of samples. Measures taken to ensure that the sampling is representative of the in situ material collected, including for instance results for field duplicate/second-half sampling. Whether sample sizes are appropriate to the grain size of the material being sampled. The nature, quality and appropriateness of the assaying and laboratory procedures used and whether the technique is considered partial or total. For geophysical tools, spectrometers, handheld XRF instruments, etc, the parameters used in determining the analysis including instrument make and model, reading times, calibrations factors applied and their derivation, etc. Nature of quality control procedures adopted (eg standards, blanks, duplicates, external laboratory checks) and whether acceptable levels of accuracy (ie lack of bias) and precision have been established. Commentary A31642 Samples were geologically logged on a 2m composite basis A34922 RAB holes geologically logged on 2 metre composite bases. DDH holes logged in detail A37495 RC holes geologically logged on one metre basis. DDH holes logged in detail A50323 RC holes were geologically logged on a one metre basis A79447 Electronic drill logs available holes logged on 2 metre composite intervals or to geological units with drillcore. A35062 RAB holes logged on a 2 metre composite basis recording major features. Drill core logged in detail A37759 RAB holes logged on a on2 metre composite basis, RC holes logged on a one metre basis, drill core logged in detail A40497 RAB holes logged on a on2 metre composite basis, RC holes logged on a one metre basis A43919 RC holes logged on a 1 metre basis, whole drill core logged A50773 RC holes logged on a 1 metre basis, whole drill core logged A57430 RC holes logged on a 1 metre basis A57430 RC holes logged on a 1 metre basis A64309 AC holes logged on a 1 metre basis A69889 RC geological logged on 1 metre basis A70039 Holes geologically logged on a one mete basis using a company standard logging code A74420 RC holes logged on a one metre basis and core logs logged to lithological units using a standard company logging code A79447 Electronic drill logs available holes logged on 2 metre composite intervals or to geological units with drillcore A46252 Criteria not reported A11589 Not relevant A22444 Criteria not provided A102002 A31642 Criteria not reported A34922 Criteria not reported. A37495 Criteria not reported A50323 One metre samples were collected via a riffle splitter, one metre wet samples were collected by grab sampling A79444 Details not provided A35062 RAB drilling no details provided an on how samples were collected. Drill core was slabbed in half with one half sent for assay A37759 No details of sampling method for RAB or RC drilling provided. Core holes were where slabbed in half with samples ranging in size from 0.78 to 1 metre in length collected. A40497 No details of sampling method for RAB or RC drilling provide A4391 No details of RC sampling provided, diamond holes were initially sampled on a 4 metre composite basis by filleting with anomalous intervals slabbed in half with one half submitted to the laboratory, sample interval ranged from 0.2 to 2.1 metres. A50773 One metre RC samples were collected by riffle splitter or grab sampled if wet. 4 metre composite samples were dispatched to laboratory. Anomalous zones were resampled at one metre intervals A57430 One metre RC samples were collected by riffle splitter or grab sampled if wet. 4 metre composite samples were dispatched to laboratory. Anomalous zones were resampled at one metre intervals A64309 No details provided A69889 No details provided A70039 4 metre composite samples collected. No mention made of submitting 1 metre samples over anomalous zones A74420 core whole slab and half core submitted for analysis on a regular one metre sample basis, RC holes 4 metre composite samples collected. A79774 Details not provided A46252 Analabs Pty Ltd Gold analysed by method GG309 lower detection limit 0.008ppm, Cu, Pb, and Zn, as by method G1201 lower detection limit 5ppm. Standard laboratory internal QAQC. No external blanks or standards submitted A11589 Not relevant A22444 Mineralised intervals analysed for Au ppm, Cu, Pb, As, Zn, Co, Ag, Ni. Laboratory details not provided A102002 A31642 Samples were analysed for Au PM209 lower detection limit 0.01 ppm, Cu (LDL 2ppm),Pb( LDL 5 ppm),Zn( LDL 2 ppm,), As LDL 20 ppm), Co (LDL 5 ppm), Bi (LDL 5ppm), by GOO1 method. Standard internal laboratory control, external standards and blanks submitted. A34922 RAB holes Samples were analysed for Au PM209 lower detection limit 0.01 ppm, Cu (LDL 2ppm),Pb( LDL 5 ppm),Zn( LDL 2 ppm,), As LDL 20 ppm), Co (LDL 5 ppm), Bi (LDL 5ppm), by GOO1 method. Standard internal laboratory control, external standards and blanks submitted. A34922 RAB holes Samples were analysed for Au PM209 lower detection limit 0.01 ppm, Cu (LDL 2ppm),Pb( LDL 5 ppm),Zn( LDL 2 ppm,), As LDL 20 ppm), Co (LDL 5 ppm), Bi (LDL 5ppm), by GOO1 method. Standard internal laboratory control, external standards and blanks submitted. DDH Laboratory criteria not provided A37495 RC samples analysed for Au and Cu only details not provided DDH samples were analysed for Au ppm, Cu, Pb Zn, As, Co, Bi, no details of laboratory or method provided A50323 Four metre composite samples were routinely assayed. 2kg sample ground in a mixer mill to nominal #75. Au analysed B/ETA (1ppb LDL) Cu (1ppm LDL), As (5ppm LDL), Pb (1ppm LDL), Bi (1 ppm LDL) analysed by AAS after aqua regia digestion. Anomalous composite samples were analysed for gold only by B/AAS (0.01ppm LDL) A53741 Four metre composite samples were routinely assayed. 2kg sample ground in a mixer mill to nominal #75. Au analysed B/ETA (1ppb LDL) Cu (1ppm LDL), as (5ppm LDL), Pb (1ppm LDL), Bi (1 ppm LDL) analysed by AAS after aqua regia digestion. Anomalous composite samples were analysed for gold only by B/AAS (0.01ppm LDL) A79774 Surrender report Digital data provided over a number of drill program with different elements analysed A35062 RAB and Core samples, analysed by Analabs, samples pulverised to nominal 200 micron, Au 50 gm fire assay (AAS) Cu, Pb, Zn, Fe perchloric acid digestion determination by AAS Co, As, Bi, W, by A/MS A37759 All samples were analysed by Analabs, samples pulverised to nominal 200 micron, Au 50 gm fire assay (AAS) Cu, Pb, Zn, Co, As Bi perchloric acid digestion determination by AAS A40497 All samples were analysed by Analabs, samples pulverised to nominal 2 | Page
View entire presentation