Development Prohibited or Restricted areas:
SI. NO
1.
2.
Low tension power lines:
Description
(a) From the portion of building accessible to persons
(b) From the portion of building inaccessible to persons
Min. Horizontal clearance-1.50m
Min. Vertical clearance -4.50m
Min. Horizontal clearance-1.25m
Min. Vertical clearance -2.50m
High tension power lines:
(c) From the portion of building accessible to persons
(d) From the portion of building inaccessible to persons
Min. Horizontal clearance-1.75m
Min. Vertical clearance -4.50m
Min.Horizontal clearance-1.25m
Min. Vertical clearance -2.50m
3.
Cremation and burial Grounds
4.
Electric/Gasified crematorium
5.
Railway tracks
Minimum Requirement
r.ramson
associates
architects & engineers
30m from the cremation or burial grounds Wherever piped water supply system not available
For construction around the crematoria site, no clearance is required; however the crematorium
structure shall be constructed with a setback of minimum 10m all around within its site
30m from the railway boundary; however with clearance obtained by the applicant from the
Railway authority concerned, constructions can be permitted
Note:
In sites which abut or affected by the alignments of the LT/HT electric over head power lines or such underground cables, constructions can be permitted only with the no objection
certificate obtained by the applicant from the TNGEDCO for such constructions.