Investor Presentaiton
NRA, Japan
Nuclear Regulation Authority
Groundwater Bypass
■ In May 2014, TEPCO started "Groundwater Bypass" to reduce
the amount of groundwater intrusion.
■ Groundwater is pumped up from the
wells upstream of T/Bs and stored in the
storage tanks and is released to the
sea after confirming that the
radioactivity concentrations are
lower than the prescribed criteria.
2. Transport to
storage tanks
3. Monitoring of
Radioactivity
1. Pumping up
from the wells
Operational Rule:
Cs-134: less than 1 Bq/L
Cs-137 less than 1 Bq/L
Total ẞ less than 5 Bq/L
H-3 less than 1,500 Bq/L
The sum of each ratio of
22
prescribed concentration limit: 0.22
汲み上げ
Turbine building
タンク
Reactor building
Hill
4. Release side
Sea
side
Groundwater flow
App. 150 m³/day reduction of groundwater
intrusion is expected.
Sea
揚水井