US-ABWR Consideration for Beyond Design Basis External Events ■US-ABWR design includes consideration for beyond design basis external events Examples -Earthquake: HCLPF (High Confidence Low Probability of Failure) capacity at least equal to twice the SSE is demonstrated for all Standard Plant safety related SSCs. -Flooding (including Tsunami): Reactor and Control Building doors are protected with tornado missile barriers, which will limit leakage due to external flooding above the design basis level. Site specific evaluation can be performed by COL applicant to add additional flood protection as necessary. -Tornado: The tornado wind speed and pressure drop in DCD are more conservative than those in R.G. 1.76 revision 1. -Extreme Wind: The tornado wind provides substantial margin above the extreme wind. (See the previous table) TOSHIBA Copyright © 2012 Toshiba Corporation. All rights reserved. Leading Innovation >>> 18